project

Ph.D.-project 'Examining in-class activities to facilitate academic achievement in higher education: a framework for optimal indoor environmental conditions'


Beschrijving

Examining in-class activities to facilitate academic achievement in higher educationThere is an increasing interest in how to create an effective and comfortable indoor environment for lecturers and students in higher education. To achieve evidence-based improvements in the indoor environmental quality (IEQ) of higher education learning environments, this research aimed to gain new knowledge for creating optimal indoor environmental conditions that best facilitate in-class activities, i.e. teaching and learning, and foster academic achievement. The academic performance of lecturers and students is subdivided into short-term academic performance, for example, during a lecture and long-term academic performance, during an academic course or year, for example. First, a systematic literature review was conducted to reveal the effect of indoor environmental quality in classrooms in higher education on the quality of teaching, the quality of learning, and students’ academic achievement. With the information gathered on the applied methods during the literature review, a systematic approach was developed and validated to capture the effect of the IEQ on the main outcomes. This approach enables research that aims to examine the effect of all four IEQ parameters, indoor air quality, thermal conditions, lighting conditions, and acoustic conditions on students’ perceptions, responses, and short-term academic performance in the context of higher education classrooms. Next, a field experiment was conducted, applying the validated systematic approach, to explore the effect of multiple indoor environmental parameters on students and their short-term academic performance in higher education. Finally, a qualitative case study gathered lecturers’ and students’ perceptions related to the IEQ. Furthermore, how these users interact with the environment to maintain an acceptable IEQ was studied.
During the systematic literature review, multiple scientific databases were searched to identify relevant scientific evidence. After the screening process, 21 publications were included. The collected evidence showed that IEQ can contribute positively to students’ academic achievement. However, it can also affect the performance of students negatively, even if the IEQ meets current standards for classrooms’ IEQ conditions. Not one optimal IEQ was identified after studying the evidence. Indoor environmental conditions in which students perform at their best differ and are task depended, indicating that classrooms should facilitate multiple indoor environmental conditions. Furthermore, the evidence provides practical information for improving the design of experimental studies, helps researchers in identifying relevant parameters, and lists methods to examine the influence of the IEQ on users.
The measurement methods deduced from the included studies of the literature review, were used for the development of a systematic approach measuring classroom IEQ and students’ perceived IEQ, internal responses, and short-term academic performance. This approach allowed studying the effect of multiple IEQ parameters simultaneously and was tested in a pilot study during a regular academic course. The perceptions, internal responses, and short-term academic performance of participating students were measured. The results show associations between natural variations of the IEQ and students’ perceptions. These perceptions were associated with their physiological and cognitive responses. Furthermore, students’ perceived cognitive responses were associated with their short-term academic performance. These observed associations confirm the construct validity of the composed systematic approach.
This systematic approach was then applied in a field experiment, to explore the effect of multiple indoor environmental parameters on students and their short-term academic performance in higher education. A field study, with a between-groups experimental design, was conducted during a regular academic course in 2020-2021 to analyze the effect of different acoustic, lighting, and indoor air quality (IAQ) conditions. First, the reverberation time was manipulated to 0.4 s in the intervention condition (control condition 0.6 s). Second, the horizontal illuminance level was raised from 500 to 750 lx in the intervention condition (control condition 500 lx). These conditions correspond with quality class A (intervention condition) and B (control condition), specified in Dutch IEQ guidelines for school buildings (2015). Third, the IAQ, which was ~1100 ppm carbon dioxide (CO2), as a proxy for IAQ, was improved to CO2 concentrations under 800 ppm, meeting quality class A in both conditions. Students’ perceptions were measured during seven campaigns with a questionnaire; their actual cognitive and short-term academic performances were evaluated with validated tests and an academic test, composed by the lecturer, as a subject-matter-expert on the taught topic, covered subjects discussed during the lecture. From 201 students 527 responses were collected and analyzed. A reduced RT in combination with raised HI improved students’ perceptions of the lighting environment, internal responses, and quality of learning. However, this experimental condition negatively influenced students’ ability to solve problems, while students' content-related test scores were not influenced. This shows that although quality class A conditions for RT and HI improved students’ perceptions, it did not influence their short-term academic performance. Furthermore, the benefits of reduced RT in combination with raised HI were not observed in improved IAQ conditions. Whether the sequential order of the experimental conditions is relevant in inducing these effects and/or whether improving two parameters is already beneficial, is unknown
Finally, a qualitative case study explored lecturers’ and students’ perceptions of the IEQ of classrooms, which are suitable to give tutorials with a maximum capacity of about 30 students. Furthermore, how lecturers and students interact with this indoor environment to maintain an acceptable IEQ was examined. Eleven lecturers of the Hanze University of Applied Sciences (UAS), located in the northern part of the Netherlands, and twenty-four of its students participated in three focus group discussions. The findings show that lecturers and students experience poor thermal, lighting, acoustic, and IAQ conditions which may influence teaching and learning performance. Furthermore, maintaining acceptable thermal and IAQ conditions was difficult for lecturers as opening windows or doors caused noise disturbances. In uncomfortable conditions, lecturers may decide to pause earlier or shorten a lecture. When students experienced discomfort, it may affect their ability to concentrate, their emotional status, and their quality of learning. Acceptable air and thermal conditions in classrooms will mitigate the need to open windows and doors. This allows lecturers to keep doors and windows closed, combining better classroom conditions with neither noise disturbances nor related distractions. Designers and engineers should take these end users’ perceptions into account, often monitored by facility management (FM), during the renovation or construction of university buildings to achieve optimal IEQ conditions in higher education classrooms.
The results of these four studies indicate that there is not a one-size fits all indoor environmental quality to facilitate optimal in-class activities. Classrooms’ thermal environment should be effectively controlled with the option of a local (manual) intervention. Classrooms’ lighting conditions should also be adjustable, both in light color and light intensity. This enables lecturers to adjust the indoor environment to facilitate in-class activities optimally. Lecturers must be informed by the building operator, for example, professionals of the Facility Department, how to change classrooms’ IEQ settings. And this may differ per classroom because each building, in which the classroom is located, is operated differently apart from the classroom location in the building, exposure to the environment, and its use. The knowledge that has come available from this study, shows that optimal indoor environmental conditions can positively influence lecturers’ and students’ comfort, health, emotional balance, and performance. These outcomes have the capacity to contribute to an improved school climate and thus academic achievement.


Producten

4
    product

    Classrooms' indoor environmental conditions affecting the academic achievement of students and teachers in higher education

    This study reports the outcomes of a systematic literature review, which aims to determine the influence of four indoor environmental parameters — indoor air, thermal, acoustic, and lighting conditions —on the quality of teaching and learning and on students' academic achievement in schools for higher education, defined as education at a college or university. By applying the Cochrane Collaboration Method, relevant scientific evidence was identified by systematically searching in multiple databases. After the screening process, 21 publications of high relevance and quality were included. The collected evidence showed that the indoor environmental quality (IEQ) can contribute positively to the quality of learning and short‐term academic performance of students. However, the influence of all parameters on the quality of teaching and the long‐term academic performance could not be determined yet. Students perform at their best in different IEQ conditions, and these conditions are task‐dependent, suggesting that classrooms which provide multiple IEQ classroom conditions facilitate different learning tasks optimally. In addition, the presented evidence illuminates how to examine the influence of the IEQ on users. Finally, this information supports decision‐makers in facility management and building systems engineering to improve the IEQ, and by doing so, allow teachers and students to perform optimally.

    PDF

    product

    A systematic approach to quantify the influence of indoor environmental parameters on students' perceptions, responses, and short-term academic performance

    Several studies found that classrooms' indoor environmental quality (IEQ) can positively influence in-class activities. Understanding and quantifying the combined effect of four indoor environmental parameters, namely indoor air quality and thermal, acoustic, and lighting conditions on people is essential to create an optimal IEQ. Accordingly, a systematic approach was developed to study the effect of multiple IEQ parameters simultaneously. Methods for measuring the IEQ and students' perceived IEQ, internal responses, and academic performance were derived from literature. Next, this systematic approach was tested in a pilot study during a regular academic course. The perceptions, internal responses, and short-term academic performance of participating students (n = 163) were measured. During the pilot study, the IEQ of the classrooms varied slightly. Significant associations (p < 0.05) were observed between these natural variations and students' perceptions of the thermal environment and indoor air quality. These perceptions were significantly associated with their physiological and cognitive responses (p < 0.05). Furthermore, students' perceived cognitive responses were associated with their short-term academic performance (p < 0.01). The observed associations confirm the construct validity of the systematic approach. However, its validity for investigating the influence of lighting remains to be determined.

    PDF

    product

    Positive effects of indoor environmental conditions on students and their performance in higher education classrooms

    This study explores if multiple alterations of the classrooms' indoor environmental conditions, which lead to environmental conditions meeting quality class A of Dutch guidelines, result in a positive effect on students' perceptions and performance. A field study, with a between-group experimental design, was conducted during the academic course in 2020–2021. First, the reverberation time (RT) was lowered in the intervention condition to 0.4 s (control condition 0.6 s). Next, the horizontal illuminance (HI) level was raised in the intervention condition to 750 lx (control condition 500 lx). Finally, the indoor air quality (IAQ) in both conditions was improved by increasing the ventilation rate, resulting in a reduction of carbon dioxide concentrations, as a proxy for IAQ, from ~1100 to