AIM To examine which instruments used to assess participation of children with acquired brain injury (ABI) or cerebral palsy (CP) align with attendance and/or involvement constructs of participation; and to systematically review measurement properties of these instruments in children with ABI or CP, to guide instrument selection. METHOD Five databases were searched. Instruments that quantified ‘attendance’ and/or ‘involvement’ aspects of participation according to the family of participation-related constructs were selected. Data on measurement properties were extracted and methodological quality of the studies assessed. RESULTS Thirty-seven instruments were used to assess participation in children with ABI or CP. Of those, 12 measured attendance and/or involvement. The reliability, validity, and responsiveness of eight of these instruments were examined in 14 studies with children with ABI or CP. Sufficient measurement properties were reported for most of the measures, but no instrument had been assessed on all relevant properties. Moreover, most psychometric studies have marked methodological limitations. INTERPRETATION Instruments to assess participation of children with ABI or CP should be selected carefully, as many available measures do not align with attendance and/or involvement. Evidence for measurement properties is limited, mainly caused by low methodological study quality. Future studies should follow recommended methodological guidelines.
AIM To examine which instruments used to assess participation of children with acquired brain injury (ABI) or cerebral palsy (CP) align with attendance and/or involvement constructs of participation; and to systematically review measurement properties of these instruments in children with ABI or CP, to guide instrument selection. METHOD Five databases were searched. Instruments that quantified ‘attendance’ and/or ‘involvement’ aspects of participation according to the family of participation-related constructs were selected. Data on measurement properties were extracted and methodological quality of the studies assessed. RESULTS Thirty-seven instruments were used to assess participation in children with ABI or CP. Of those, 12 measured attendance and/or involvement. The reliability, validity, and responsiveness of eight of these instruments were examined in 14 studies with children with ABI or CP. Sufficient measurement properties were reported for most of the measures, but no instrument had been assessed on all relevant properties. Moreover, most psychometric studies have marked methodological limitations. INTERPRETATION Instruments to assess participation of children with ABI or CP should be selected carefully, as many available measures do not align with attendance and/or involvement. Evidence for measurement properties is limited, mainly caused by low methodological study quality. Future studies should follow recommended methodological guidelines.
Light therapy is increasingly administered and studied as a non-pharmacologic treatment for a variety of healthrelated problems, including treatment of people with dementia. Light therapy comes in a variety of ways, ranging from being exposed to daylight, to being exposed to light emitted by light boxes and ambient bright light. Light therapy is an area in medicine where medical sciences meet the realms of physics, engineering and technology. Therefore, it is paramount that attention is paid in the methodology of studies to the technical aspects in their full breadth. This paper provides an extensive introduction for non-technical researchers on how to describe and adjust their methodology when involved in lighting therapy research. A specific focus in this manuscript is on ambient bright light, as it is an emerging field within the domain of light therapy. The paper deals with how to (i) describe the lighting equipment, (ii) describe the light measurements, (iii) describe the building and interaction with daylight. Moreover, attention is paid to the uncertainty in standards and guidelines regarding light and lighting for older adults.
Size measurement plays an essential role for micro-/nanoparticle characterization and property evaluation. Due to high costs, complex operation or resolution limit, conventional characterization techniques cannot satisfy the growing demand of routine size measurements in various industry sectors and research departments, e.g., pharmaceuticals, nanomaterials and food industry etc. Together with start-up SeeNano and other partners, we will develop a portable compact device to measure particle size based on particle-impact electrochemical sensing technology. The main task in this project is to extend the measurement range for particles with diameters ranging from 20 nm to 20 um and to validate this technology with realistic samples from various application areas. In this project a new electrode chip will be designed and fabricated. It will result in a workable prototype including new UMEs (ultra-micro electrode), showing that particle sizing can be achieved on a compact portable device with full measuring range. Following experimental testing with calibrated particles, a reliable calibration model will be built up for full range measurement. In a further step, samples from partners or potential customers will be tested on the device to evaluate the application feasibility. The results will be validated by high-resolution and mainstream sizing techniques such as scanning electron microscopy (SEM), dynamic light scattering (DLS) and Coulter counter.
Examining in-class activities to facilitate academic achievement in higher educationThere is an increasing interest in how to create an effective and comfortable indoor environment for lecturers and students in higher education. To achieve evidence-based improvements in the indoor environmental quality (IEQ) of higher education learning environments, this research aimed to gain new knowledge for creating optimal indoor environmental conditions that best facilitate in-class activities, i.e. teaching and learning, and foster academic achievement. The academic performance of lecturers and students is subdivided into short-term academic performance, for example, during a lecture and long-term academic performance, during an academic course or year, for example. First, a systematic literature review was conducted to reveal the effect of indoor environmental quality in classrooms in higher education on the quality of teaching, the quality of learning, and students’ academic achievement. With the information gathered on the applied methods during the literature review, a systematic approach was developed and validated to capture the effect of the IEQ on the main outcomes. This approach enables research that aims to examine the effect of all four IEQ parameters, indoor air quality, thermal conditions, lighting conditions, and acoustic conditions on students’ perceptions, responses, and short-term academic performance in the context of higher education classrooms. Next, a field experiment was conducted, applying the validated systematic approach, to explore the effect of multiple indoor environmental parameters on students and their short-term academic performance in higher education. Finally, a qualitative case study gathered lecturers’ and students’ perceptions related to the IEQ. Furthermore, how these users interact with the environment to maintain an acceptable IEQ was studied.During the systematic literature review, multiple scientific databases were searched to identify relevant scientific evidence. After the screening process, 21 publications were included. The collected evidence showed that IEQ can contribute positively to students’ academic achievement. However, it can also affect the performance of students negatively, even if the IEQ meets current standards for classrooms’ IEQ conditions. Not one optimal IEQ was identified after studying the evidence. Indoor environmental conditions in which students perform at their best differ and are task depended, indicating that classrooms should facilitate multiple indoor environmental conditions. Furthermore, the evidence provides practical information for improving the design of experimental studies, helps researchers in identifying relevant parameters, and lists methods to examine the influence of the IEQ on users.The measurement methods deduced from the included studies of the literature review, were used for the development of a systematic approach measuring classroom IEQ and students’ perceived IEQ, internal responses, and short-term academic performance. This approach allowed studying the effect of multiple IEQ parameters simultaneously and was tested in a pilot study during a regular academic course. The perceptions, internal responses, and short-term academic performance of participating students were measured. The results show associations between natural variations of the IEQ and students’ perceptions. These perceptions were associated with their physiological and cognitive responses. Furthermore, students’ perceived cognitive responses were associated with their short-term academic performance. These observed associations confirm the construct validity of the composed systematic approach. This systematic approach was then applied in a field experiment, to explore the effect of multiple indoor environmental parameters on students and their short-term academic performance in higher education. A field study, with a between-groups experimental design, was conducted during a regular academic course in 2020-2021 to analyze the effect of different acoustic, lighting, and indoor air quality (IAQ) conditions. First, the reverberation time was manipulated to 0.4 s in the intervention condition (control condition 0.6 s). Second, the horizontal illuminance level was raised from 500 to 750 lx in the intervention condition (control condition 500 lx). These conditions correspond with quality class A (intervention condition) and B (control condition), specified in Dutch IEQ guidelines for school buildings (2015). Third, the IAQ, which was ~1100 ppm carbon dioxide (CO2), as a proxy for IAQ, was improved to CO2 concentrations under 800 ppm, meeting quality class A in both conditions. Students’ perceptions were measured during seven campaigns with a questionnaire; their actual cognitive and short-term academic performances were evaluated with validated tests and an academic test, composed by the lecturer, as a subject-matter-expert on the taught topic, covered subjects discussed during the lecture. From 201 students 527 responses were collected and analyzed. A reduced RT in combination with raised HI improved students’ perceptions of the lighting environment, internal responses, and quality of learning. However, this experimental condition negatively influenced students’ ability to solve problems, while students' content-related test scores were not influenced. This shows that although quality class A conditions for RT and HI improved students’ perceptions, it did not influence their short-term academic performance. Furthermore, the benefits of reduced RT in combination with raised HI were not observed in improved IAQ conditions. Whether the sequential order of the experimental conditions is relevant in inducing these effects and/or whether improving two parameters is already beneficial, is unknownFinally, a qualitative case study explored lecturers’ and students’ perceptions of the IEQ of classrooms, which are suitable to give tutorials with a maximum capacity of about 30 students. Furthermore, how lecturers and students interact with this indoor environment to maintain an acceptable IEQ was examined. Eleven lecturers of the Hanze University of Applied Sciences (UAS), located in the northern part of the Netherlands, and twenty-four of its students participated in three focus group discussions. The findings show that lecturers and students experience poor thermal, lighting, acoustic, and IAQ conditions which may influence teaching and learning performance. Furthermore, maintaining acceptable thermal and IAQ conditions was difficult for lecturers as opening windows or doors caused noise disturbances. In uncomfortable conditions, lecturers may decide to pause earlier or shorten a lecture. When students experienced discomfort, it may affect their ability to concentrate, their emotional status, and their quality of learning. Acceptable air and thermal conditions in classrooms will mitigate the need to open windows and doors. This allows lecturers to keep doors and windows closed, combining better classroom conditions with neither noise disturbances nor related distractions. Designers and engineers should take these end users’ perceptions into account, often monitored by facility management (FM), during the renovation or construction of university buildings to achieve optimal IEQ conditions in higher education classrooms.The results of these four studies indicate that there is not a one-size fits all indoor environmental quality to facilitate optimal in-class activities. Classrooms’ thermal environment should be effectively controlled with the option of a local (manual) intervention. Classrooms’ lighting conditions should also be adjustable, both in light color and light intensity. This enables lecturers to adjust the indoor environment to facilitate in-class activities optimally. Lecturers must be informed by the building operator, for example, professionals of the Facility Department, how to change classrooms’ IEQ settings. And this may differ per classroom because each building, in which the classroom is located, is operated differently apart from the classroom location in the building, exposure to the environment, and its use. The knowledge that has come available from this study, shows that optimal indoor environmental conditions can positively influence lecturers’ and students’ comfort, health, emotional balance, and performance. These outcomes have the capacity to contribute to an improved school climate and thus academic achievement.
The building industry is a major target for resource-efficiency developments, which are crucial in European Union’s roadmaps. Using renewable materials impacts the sustainability of buildings and is set as urgent target in current architectural practice. The building industry needs renewable materials positively impacting the CO2 footprint without drawbacks. The use of wood and timber as renewable construction materials has potentials, but also drawbacks because trees need long time to grow; producing timber generates considerable waste; and the process from trees to applications in buildings requires transportation and CO2 emission. This research generates new scientific knowledge and a feasibility study for a new wood-like bio-material - made of cellulose and lignin from (local) residual biomass via i.e. 3D printing - suitable for applications in the building industry. It contributes to a sustainable built environment as it transforms waste from different sectors into a local resource to produce a low carbon-footprint bio-material for the construction sector. Through testing, the project will study the material properties of samples of raw and 3D printed material, correlating different material recipes that combine lignin and cellulose and different 3D printing production parameters. It will map the material properties with the requirements of the construction industry for different building products, indicating potentials and limits of the proposed bio-material. The project will produce new knowledge on the material properties, a preliminary production concept and an overview of potentials and limits for application in the built environment. The outcome will be used by industry to achieve a marketable new bio-material; as well as in further scientific academic research.