Service of SURF
© 2025 SURF
In recent years, the number of human-induced earthquakes in Groningen, a large gas field in the north of the Netherlands, has increased. The majority of the buildings are built by using unreinforced masonry (URM), most of which consists of cavity (i.e. two-leaf) walls, and were not designed to withstand earthquakes. Efforts to define, test and standardize the metal ties, which do play an important role, are valuable also from the wider construction industry point of view. The presented study exhibits findings on the behavior of the metal tie connections between the masonry leaves often used in Dutch construction practice, but also elsewhere around the world. An experimental campaign has been carried out at Delft University of Technology to provide a complete characterization of the axial behavior of traditional connections in cavity walls. A large number of variations was considered in this research: two embedment lengths, four pre-compression levels, two different tie geometries, and five different testing protocols, including monotonic and cyclic loading. The experimental results showed that the capacity of the connection was strongly influenced by the embedment length and the geometry of the tie, whereas the applied pre-compression and the loading rate did not have a significant influence.
This paper aims to quantify the evolution of damage in masonry walls under induced seismicity. A damage index equation, which is a function of the evolution of shear slippage and opening of the mortar joints, as well as of the drift ratio of masonry walls, was proposed herein. Initially, a dataset of experimental tests from in-plane quasi-static and cyclic tests on masonry walls was considered. The experimentally obtained crack patterns were investigated and their correlation with damage propagation was studied. Using a software based on the Distinct Element Method, a numerical model was developed and validated against full-scale experimental tests obtained from the literature. Wall panels representing common typologies of house façades of unreinforced masonry buildings in Northern Europe i.e. near the Groningen gas field in the Netherlands, were numerically investigated. The accumulated damage within the seismic response of the masonry walls was investigated by means of representative harmonic load excitations and an incremental dynamic analysis based on induced seismicity records from Groningen region. The ability of this index to capture different damage situations is demonstrated. The proposed methodology could also be applied to quantify damage and accumulation in masonry during strong earthquakes and aftershocks too.
The assessment of the out-of-plane response of unreinforced masonry (URM) buildings with cavity walls has been a popular topic in regions such as Central and Northern Europe, Australia, New Zealand, China and several other countries.Cavity walls are particularly vulnerable as the out-of-plane capacity of each individual leaf is significantly smaller than the one of a solid wall. In the Netherlands, cavity walls are characterized by an inner load-bearing leaf of calcium silicate bricks, and by an outer veneer of clay bricks that has only aesthetic and insulation functions. The two leaves are typically connected by means of metallic ties. This paper utilizes the results of an experimental campaign conducted by the authors to calibrate a hysteretic model that represents the axial cyclic response of cavity wall tie connections. The proposednumerical model uses zero-length elements implemented in OpenSees with the Pinching4 constitutive model to account for the compression-tension cyclic behaviour of the ties. The numerical model is able to capture important aspects of the tie response such as the strength degradation, the unloading stiffness degradation and the pinching behaviour. The numerical modelling approach in this paper can be easily adopted by practitioner engineers who aim to model the wall ties more accurately when assessing the structures against earthquakes.
A series of tests performed on as-built and strengthened timber joist-masonry-wall specimens. The test aims at providing a complete characterization of the behaviour of the timber-joist connections under axial cyclic loading. The obtained results will be used as inputs to calibrate numerical models to simulate the connection between the cavity wall and timber joist.
Post-earthquake structural damage shows that wall collapse is one of the most common failure mechanisms in unreinforced masonry buildings. It is expected to be a critical issue also in Groningen, located in the northern part of the Netherlands, where human-induced seismicity has become an uprising problem in recent years. The majority of the existing buildings in that area are composed of unreinforced masonry; they were not designed to withstand earthquakes since the area has never been affected by tectonic earthquakes. They are characterised by vulnerable structural elements such as slender walls, large openings and cavity walls. Hence, the assessment of unreinforced masonry buildings in the Groningen province has become of high relevance. The abovementioned issue motivates engineering companies in the region to research seismic assessments of the existing structures. One of the biggest challenges is to be able to monitor structures during events in order to provide a quick post-earthquake assessment hence to obtain progressive damage on structures. The research published in the literature shows that crack detection can be a very powerful tool as an assessment technique. In order to ensure an adequate measurement, state-of-art technologies can be used for crack detection, such as special sensors or deep learning techniques for pixel-level crack segmentation on masonry surfaces. In this project, a new experiment will be run on an in-plane test setup to systematically propagate cracks to be able to detect cracks by new crack detection tools, namely digital crack sensor and vision-based crack detection. The validated product of the experiment will be tested on the monument of Fraeylemaborg.
The Ph.D. candidate will investigate the seismic response of connection details frequently used in traditional Dutch construction practice, specifically in the Groningen area. The research will focus on the experimental and numerical definition of the complete load-deflection behaviour of each considered connection; specifically, the tests will aim at identifying stiffness, strength, ductility, and dissipative behaviour of the connections. The experiments will be conducted on scaled or full-scale components that properly resemble the as-built and retrofitted as well connection details. The tests will involve monotonic and cyclic loading protocols to be able to define the load and displacement response of the connection to reversal loads, such as earthquakes, as well as the development of failure mechanisms under such loading cases. Possibly, also dynamic tests will be performed. Numerical models will be created and calibrated versus the experimental findings. Characteristic hysteretic behaviours of the examined connection types will be provided for the use of engineers and researchers.