Service of SURF
© 2025 SURF
The main goal of this study is to identify knowledge gaps and uncertainties in Quantitative Risk Assessments (QRA) for CO2 pipelines and to assess to what extent those gaps and uncertainties affect the final outcome of the QRA. The impact of methodological choices and uncertain values for input parameters on the results of QRA’s have been assessed through an extensive literature review and by using commercially available release, dispersion and effect models. It is made apparent that over the full life cycle of a QRA knowledge gaps and uncertainties are present that may have large scale impact on the accuracy of assessing risks of CO2 pipelines. These encompass the invalidated release and dispersion models, the currently used failure rates, choosing the type of release to be modeled and the dose-effect relationships assumed. Also recommendations are presented for the improvement of QRA’s for CO2 pipelines.
MULTIFILE
Nederlandse gemeenten hebben te maken met een grote bouwopgave. Dit zorgt voor veel voertuigbewegingen van en naar bouwprojecten. In 2021 werd er meer dan 250 miljoen ton bouwmaterialen vervoerd in Nederland. Daarmee is de bouw de grootste vervoerende sector in tonnen. Op de snelwegen transporteert één op de vijf vrachtwagens bouwmaterialen, in steden is dat één op de vier. Ook financieel gezien is de impact groot: de logistieke kosten in de bouwsector bedragen ruim € 6 miljard per jaar. Uiteraard is ook de CO2-uitstoot een belangrijk agendapunt: het aandeel van transport in de totale CO2-uitstoot van de bouwsector bedraagt maar liefst 35%. De vraag doet zich daarom voor: hoe kan de bouwlogistiek beter worden geregeld? De Topsector Logistiek onderzocht het.
A (semi-)closed greenhouse is a novel greenhouse with an active cooling system and temporary heat storage in an aquifer. Air is cooled, heated and dehumidified by air treatment units. Climate in (semi-)closed greenhouses differs from that of conventional open greenhouses. The aims of our research were first, to analyze the effect of active cooling on greenhouse climate, in terms of stability, gradient and average levels; second, to determine crop growth and production in closed and semi-closed greenhouses. An experiment with tomato crop was conducted from December 2007 until November 2008 in a closed greenhouse with 700 W m-2 cooling capacity, two semi-closed greenhouses with 350 and 150 W m-2 cooling capacity, respectively, and an open greenhouse. The higher the cooling capacity, the more independent the greenhouse climate was of the outside climate. As the cooling ducts were placed underneath the plants, cooling led to a remarkable vertical temperature gradient. Under sunny conditions temperature could be 5°C higher at the top than at the bottom of the canopy in the closed greenhouse. Cumulative production in the semi-closed greenhouses with 350 and 150 W m-2 cooling capacity were 10% (61 kg m-2) and 6% (59 kg m-2) higher than that in the open greenhouse (55 kg m-2), respectively. Cumulative production in the closed greenhouse was 14% higher than in the open greenhouse in week 29 after planting but at the end of the experiment the cumulative increase was only 4% due to botrytis. Model calculations showed that the production increase in the closed and semi-closed greenhouses was explained by higher CO2 concentration.
LINK
Climate change is one of the most critical global challenges nowadays. Increasing atmospheric CO2 concentration brought by anthropogenic emissions has been recognized as the primary driver of global warming. Therefore, currently, there is a strong demand within the chemical and chemical technology industry for systems that can covert, capture and reuse/recover CO2. Few examples can be seen in the literature: Hamelers et al (2013) presented systems that can use CO2 aqueous solutions to produce energy using electrochemical cells with porous electrodes; Legrand et al (2018) has proven that CDI can be used to capture CO2 without solvents; Shu et al (2020) have used electrochemical systems to desorb (recover) CO2 from an alkaline absorbent with low energy demand. Even though many efforts have been done, there is still demand for efficient and market-ready systems, especially related to solvent-free CO2 capturing systems. This project intends to assess a relatively efficient technology, with low-energy costs which can change the CO2 capturing market. This technology is called whorlpipe. The whorlpipe, developed by Viktor Schauberger, has shown already promising results in reducing the energy and CO2 emissions for water pumping. Recently, studies conducted by Wetsus and NHL Stenden (under submission), in combination with different companies (also members in this proposal) have shown that vortices like systems, like the Schauberger funnel, and thus “whorlpipe”, can be fluid dynamically represented using Taylor-Couette flows. This means that such systems have a strong tendency to form vortices like fluid-patterns close to their air-water interface. Such flow system drastically increase advection. Combined with their higher area to volume ratio, which increases diffusion, these systems can greatly enhance gas capturing (in liquids), and are, thus, a unique opportunity for CO2 uptake from the air, i.e. competing with systems like conventional scrubbers or bubble-based aeration.
Cell-based production processes in bioreactors and fermenters need to be carefully monitored due to the complexity of the biological systems and the growth processes of the cells. Critical parameters are identified and monitored over time to guarantee product quality and consistency and to minimize over-processing and batch rejections. Sensors are already available for monitoring parameters such as temperature, glucose, pH, and CO2, but not yet for low-concentration substances like proteins and nucleic acids (DNA). An interesting critical parameter to monitor is host cell DNA (HCD), as it is considered an impurity in the final product (downstream process) and its concentration indicates the cell status (upstream process). The Molecular Biosensing group at the Eindhoven University of Technology and Helia Biomonitoring are developing a sensor for continuous biomarker monitoring, based on Biosensing by Particle Motion. With this consortium, we want to explore whether the sensor is suitable for the continuous measurement of HCD. Therefore, we need to set-up a joint laboratory infrastructure to develop HCD assays. Knowledge of how cells respond to environmental changes and how this is reflected in the DNA concentration profile in the cell medium needs to be explored. This KIEM study will enable us to set the first steps towards continuous HCD sensing from cell culture conditions controlling cell production processes. It eventually generates input for machine learning to be able to automate processes in bioreactors and fermenters e.g. for the production of biopharmaceuticals. The project entails collaboration with new partners and will set a strong basis for subsequent research projects leading to scientific and economic growth, and will also contribute to the human capital agenda.
Examining in-class activities to facilitate academic achievement in higher educationThere is an increasing interest in how to create an effective and comfortable indoor environment for lecturers and students in higher education. To achieve evidence-based improvements in the indoor environmental quality (IEQ) of higher education learning environments, this research aimed to gain new knowledge for creating optimal indoor environmental conditions that best facilitate in-class activities, i.e. teaching and learning, and foster academic achievement. The academic performance of lecturers and students is subdivided into short-term academic performance, for example, during a lecture and long-term academic performance, during an academic course or year, for example. First, a systematic literature review was conducted to reveal the effect of indoor environmental quality in classrooms in higher education on the quality of teaching, the quality of learning, and students’ academic achievement. With the information gathered on the applied methods during the literature review, a systematic approach was developed and validated to capture the effect of the IEQ on the main outcomes. This approach enables research that aims to examine the effect of all four IEQ parameters, indoor air quality, thermal conditions, lighting conditions, and acoustic conditions on students’ perceptions, responses, and short-term academic performance in the context of higher education classrooms. Next, a field experiment was conducted, applying the validated systematic approach, to explore the effect of multiple indoor environmental parameters on students and their short-term academic performance in higher education. Finally, a qualitative case study gathered lecturers’ and students’ perceptions related to the IEQ. Furthermore, how these users interact with the environment to maintain an acceptable IEQ was studied.During the systematic literature review, multiple scientific databases were searched to identify relevant scientific evidence. After the screening process, 21 publications were included. The collected evidence showed that IEQ can contribute positively to students’ academic achievement. However, it can also affect the performance of students negatively, even if the IEQ meets current standards for classrooms’ IEQ conditions. Not one optimal IEQ was identified after studying the evidence. Indoor environmental conditions in which students perform at their best differ and are task depended, indicating that classrooms should facilitate multiple indoor environmental conditions. Furthermore, the evidence provides practical information for improving the design of experimental studies, helps researchers in identifying relevant parameters, and lists methods to examine the influence of the IEQ on users.The measurement methods deduced from the included studies of the literature review, were used for the development of a systematic approach measuring classroom IEQ and students’ perceived IEQ, internal responses, and short-term academic performance. This approach allowed studying the effect of multiple IEQ parameters simultaneously and was tested in a pilot study during a regular academic course. The perceptions, internal responses, and short-term academic performance of participating students were measured. The results show associations between natural variations of the IEQ and students’ perceptions. These perceptions were associated with their physiological and cognitive responses. Furthermore, students’ perceived cognitive responses were associated with their short-term academic performance. These observed associations confirm the construct validity of the composed systematic approach. This systematic approach was then applied in a field experiment, to explore the effect of multiple indoor environmental parameters on students and their short-term academic performance in higher education. A field study, with a between-groups experimental design, was conducted during a regular academic course in 2020-2021 to analyze the effect of different acoustic, lighting, and indoor air quality (IAQ) conditions. First, the reverberation time was manipulated to 0.4 s in the intervention condition (control condition 0.6 s). Second, the horizontal illuminance level was raised from 500 to 750 lx in the intervention condition (control condition 500 lx). These conditions correspond with quality class A (intervention condition) and B (control condition), specified in Dutch IEQ guidelines for school buildings (2015). Third, the IAQ, which was ~1100 ppm carbon dioxide (CO2), as a proxy for IAQ, was improved to CO2 concentrations under 800 ppm, meeting quality class A in both conditions. Students’ perceptions were measured during seven campaigns with a questionnaire; their actual cognitive and short-term academic performances were evaluated with validated tests and an academic test, composed by the lecturer, as a subject-matter-expert on the taught topic, covered subjects discussed during the lecture. From 201 students 527 responses were collected and analyzed. A reduced RT in combination with raised HI improved students’ perceptions of the lighting environment, internal responses, and quality of learning. However, this experimental condition negatively influenced students’ ability to solve problems, while students' content-related test scores were not influenced. This shows that although quality class A conditions for RT and HI improved students’ perceptions, it did not influence their short-term academic performance. Furthermore, the benefits of reduced RT in combination with raised HI were not observed in improved IAQ conditions. Whether the sequential order of the experimental conditions is relevant in inducing these effects and/or whether improving two parameters is already beneficial, is unknownFinally, a qualitative case study explored lecturers’ and students’ perceptions of the IEQ of classrooms, which are suitable to give tutorials with a maximum capacity of about 30 students. Furthermore, how lecturers and students interact with this indoor environment to maintain an acceptable IEQ was examined. Eleven lecturers of the Hanze University of Applied Sciences (UAS), located in the northern part of the Netherlands, and twenty-four of its students participated in three focus group discussions. The findings show that lecturers and students experience poor thermal, lighting, acoustic, and IAQ conditions which may influence teaching and learning performance. Furthermore, maintaining acceptable thermal and IAQ conditions was difficult for lecturers as opening windows or doors caused noise disturbances. In uncomfortable conditions, lecturers may decide to pause earlier or shorten a lecture. When students experienced discomfort, it may affect their ability to concentrate, their emotional status, and their quality of learning. Acceptable air and thermal conditions in classrooms will mitigate the need to open windows and doors. This allows lecturers to keep doors and windows closed, combining better classroom conditions with neither noise disturbances nor related distractions. Designers and engineers should take these end users’ perceptions into account, often monitored by facility management (FM), during the renovation or construction of university buildings to achieve optimal IEQ conditions in higher education classrooms.The results of these four studies indicate that there is not a one-size fits all indoor environmental quality to facilitate optimal in-class activities. Classrooms’ thermal environment should be effectively controlled with the option of a local (manual) intervention. Classrooms’ lighting conditions should also be adjustable, both in light color and light intensity. This enables lecturers to adjust the indoor environment to facilitate in-class activities optimally. Lecturers must be informed by the building operator, for example, professionals of the Facility Department, how to change classrooms’ IEQ settings. And this may differ per classroom because each building, in which the classroom is located, is operated differently apart from the classroom location in the building, exposure to the environment, and its use. The knowledge that has come available from this study, shows that optimal indoor environmental conditions can positively influence lecturers’ and students’ comfort, health, emotional balance, and performance. These outcomes have the capacity to contribute to an improved school climate and thus academic achievement.