Dienst van SURF
© 2025 SURF
Knowing firefighters’ locations in a burning building would dramatically improve their safety. In this study from the Saxion Research Centre for Design and Technology in the Firebee project, an algorithm was developed and tested to enhance the estimation of a person’s location, based on inertial measurements combined with measurements of the earth’s magnetic field. The developed algorithm is an extension of the zero velocity update technique. Without any enhancements, the accuracy of the estimation is in the order of several meters after measuring for only a few seconds. With enhancements, the accuracy improved to be within five meters after measuring for ten minutes. Our result demonstrated that it is possible to determine in which room and on which floor a person is after ten minutes. Major improvements were observed in the estimation of the sensor’s height. The results are promising and the following phases of the project focus on improving the solution and on developing the concept into a practically applicable system.
MULTIFILE
Knowledge of spatial and temporal trends in the environmental exposure to radiofrequency electromagnetic fields (RF-EMF) is a key prerequisite for RF-EMF risk assessment studies attempting to establish a link between RF-EMF and potential effects on human health as well as on fauna and flora. In this paper, we determined the validity of RF exposure modelling based on inner-area kriging interpolation of measurements on the surrounding streets. The results vary depending on area size and shape and structural factors; a Spearman coefficient of 0.8 and a relative error of less than 3.5 dB are achieved on a data set featuring a closed measurement ring around a decently sized area (1 km2, with an average minimum distance of the encircled area to the ring of less than 100 m), containing mainly low, detached buildings. In larger areas, additional inner-area sampling is advised, lowering the average minimum distance between sampled and interpolated locations to 100 m, to achieve the same level of accuracy. https://doi.org/10.1016/j.envint.2016.06.006 LinkedIn: https://www.linkedin.com/in/john-bolte-0856134/
Purpose: Accurate measurement of body temperature is important for the timely detection of fever or hypothermia in critically ill patients. In this prospective study, we evaluated whether the agreement between temperature measurements obtained with TAT (test method) and bladder catheter-derived temperature measurements (BT; reference method) is sufficient for clinical practice in critically ill patients. Methods: Patients acutely admitted to the Intensive Care Unit were included. After BT was recorded TAT measurements were performed by two independent researchers (TAT1; TAT2). The agreement between TAT and BT was assessed using Bland-Altman plots. Clinical acceptable limits of agreement (LOA) were defined a priori (<0.5°C). Subgroup analysis was performed in patients receiving norepinephrine. Results: In total, 90 critically ill patients (64 males; mean age 62 years) were included. The observed mean difference (TAT-BT; ±SD, 95% LOA) between TAT and BT was 0.12°C (-1.08°C to +1.32°C) for TAT1 and 0.14°C (-1.05°C to +1.33°C) for TAT2. 36% (TAT1) and 42% (TAT2) of all paired measurements failed to meet the acceptable LOA of 0.5°C. Subgroup analysis showed that when patients were receiving intravenous norepinephrine, the measurements of the test method deviated more from the reference method (p = NS). Conclusion: The TAT is not sufficient for clinical practice in critically ill adults
LINK
Size measurement plays an essential role for micro-/nanoparticle characterization and property evaluation. Due to high costs, complex operation or resolution limit, conventional characterization techniques cannot satisfy the growing demand of routine size measurements in various industry sectors and research departments, e.g., pharmaceuticals, nanomaterials and food industry etc. Together with start-up SeeNano and other partners, we will develop a portable compact device to measure particle size based on particle-impact electrochemical sensing technology. The main task in this project is to extend the measurement range for particles with diameters ranging from 20 nm to 20 um and to validate this technology with realistic samples from various application areas. In this project a new electrode chip will be designed and fabricated. It will result in a workable prototype including new UMEs (ultra-micro electrode), showing that particle sizing can be achieved on a compact portable device with full measuring range. Following experimental testing with calibrated particles, a reliable calibration model will be built up for full range measurement. In a further step, samples from partners or potential customers will be tested on the device to evaluate the application feasibility. The results will be validated by high-resolution and mainstream sizing techniques such as scanning electron microscopy (SEM), dynamic light scattering (DLS) and Coulter counter.
The denim industry faces many complex sustainability challenges and has been especially criticized for its polluting and hazardous production practices. Reducing resource use of water, chemicals and energy and changing denim production practices calls for collaboration between various stakeholders, including competing denim brands. There is great benefit in combining denim brands’ resources and knowledge so that commonly defined standards and benchmarks are developed and realized on a scale that matters. Collaboration however, and especially between competitors, is highly complex and prone to fail. This project brings leading denim brands together to collectively take initial steps towards improving the ecological sustainability impact of denim production, particularly by establishing measurements, benchmarks and standards for resource use (e.g. chemicals, water, energy) and creating best practices for effective collaboration. The central research question of our project is: How do denim brands effectively collaborate together to create common, industry standards on resource use and benchmarks for improved ecological sustainability in denim production? To answer this question, we will use a mixed-method, action research approach. The project’s research setting is the Amsterdam Metropolitan Area (MRA), which has a strong denim cluster and is home to many international denim brands and start-ups.
The AR in Staged Entertainment project focuses on utilizing immersive technologies to strengthen performances and create resiliency in live events. In this project The Experiencelab at BUas explores this by comparing live as well as pre-recorded events that utilize Augmented Reality technology to provide an added layer to the experience of the user. Experiences will be measured among others through observational measurements using biometrics. This projects runs in the Experience lab of BUas with partners The Effenaar and 4DR Studio and is connected to the networks and goals related to Chronosphere, Digireal and Makerspace. Project is powered by Fieldlab Events (PPS / ClickNL)..