A prototype of an indoor monoblock heat pump was tested at multiple ambient temperatures, to determine heat output, COP and the impact of defrosting events. Component efficiencies and the ice accumulation process were analysed. Options to improve performance were suggested.
Research has been done on how the implementation of heat pumps in dwellings could have the maximum impact on energy savings.
The neighborhood of Houtlaan in Assen, the Netherlands, has ambitious targets for reducing the neighborhood’scarbon emissions and increasing their production of their own, sustainable energy. Specifically, they wish toincrease the percentage of houses with a heat pump, electric vehicle (EV) and solar panels (PV) to 60%, 70%and 80%, respectively, by the year 2030. However, it was unclear what the impacts of this transition would be onthe electricity grid, and what limitations or problems might be encountered along the way.Therefore, a study was carried out to model the future energy load and production patterns in Houtlaan. Thepurpose of the model was to identify and quantify the problems which could be encountered if no steps are takento prevent these problems. In addition, the model was used to simulate the effectiveness of various proposedsolutions to reduce or eliminate the problems which were identified.
Residential electricity distribution grid capacity is based on the typical peak load of a house and the load simultaneity factor. Historically, these values have remained predictable, but this is expected to change due to increasing electric heating using heat pumps and rooftop solar panel electricity generation. It is currently unclear how this increase in electrification will impact household peak load and load simultaneity, and hence the required grid capacity of residential electricity distribution grids. To gain better insight, transformer and household load measurements were taken in an all-electric neighborhood over a period of three years. These measurements were analyzed to determine how heat pumps and solar panels will alter peak load and load simultaneity, and hence grid capacity requirements. The impacts of outdoor effective temperature and solar panel orientation were also analyzed. Moreover, the potential for smart grids to reduce grid capacity requirements was examined.
In this research, the experiences and behaviors of end-users in a smart grid project are explored. In PowerMatching City, the leading Dutch smart grid project, 40 households were equipped with various decentralized energy sources (PV and microCHP), hybrid heat pumps, smart appliances, smart meters and an in-home display. Stabilization and optimization of the network was realized by trading energy on the market. To reduce peak loads on the smart grid, several types of demand side management were tested. Households received feedback on their energy use either based on costs, or on the percentage of consumed energy that had been produced locally. Furthermore, devices could be controlled automatically, smartly or manually to optimize the energy use of the households. Results from quantitative and qualitative research showed that: (1) feedback on costs reduction is valued most; (2) end-users preferred to consume self-produced energy (this may even be the case when, from a cost or sustainability perspective, it is not the most efficient strategy to follow); (3) automatic and smart control are most popular, but manually controlling appliances is more rewarding; (4) experiences and behaviors of end-users depended on trust between community members, and on trust in both technology (ICT infrastructure and connected appliances) and the participating parties.
Hybrid Energy Storage System (HESS) have the potential to offer better flexibility to a grid than any single energy storage solution. However, sizing a HESS is challenging, as the required capacity, power and ramp rates for a given application are difficult to derive. This paper proposes a method for splitting a given load profile into several storage technology independent sub-profiles, such that each of the sub-profiles leads to its own requirements. This method can be used to gain preliminary insight into HESS requirements before a choice is made for specific storage technologies. To test the method, a household case is investigated using the derived methodology, and storage requirements are found, which can then be used to derive concrete storage technologies for the HESS of the household. Adding a HESS to the household case reduces the maximum import power from the connected grid by approximately 7000 W and the maximum exported power to the connected grid by approximately 1000 W. It is concluded that the method is particularly suitable for data sets with a high granularity and many data points.
MULTIFILE
The Heating Ventilation and Air Conditioning (HVAC) sector is responsible for a large part of the total worldwide energy consumption, a significant part of which is caused by incorrect operation of controls and maintenance. HVAC systems are becoming increasingly complex, especially due to multi-commodity energy sources, and as a result, the chance of failures in systems and controls will increase. Therefore, systems that diagnose energy performance are of paramount importance. However, despite much research on Fault Detection and Diagnosis (FDD) methods for HVAC systems, they are rarely applied. One major reason is that proposed methods are different from the approaches taken by HVAC designers who employ process and instrumentation diagrams (P&IDs). This led to the following main research question: Which FDD architecture is suitable for HVAC systems in general to support the set up and implementation of FDD methods, including energy performance diagnosis? First, an energy performance FDD architecture based on information embedded in P&IDs was elaborated. The new FDD method, called the 4S3F method, combines systems theory with data analysis. In the 4S3F method, the detection and diagnosis phases are separated. The symptoms and faults are classified into 4 types of symptoms (deviations from balance equations, operating states (OS) and energy performance (EP), and additional information) and 3 types of faults (component, control and model faults). Second, the 4S3F method has been tested in four case studies. In the first case study, the symptom detection part was tested using historical Building Management System (BMS) data for a whole year: the combined heat and power plant of the THUAS (The Hague University of Applied Sciences) building in Delft, including an aquifer thermal energy storage (ATES) system, a heat pump, a gas boiler and hot and cold water hydronic systems. This case study showed that balance, EP and OS symptoms can be extracted from the P&ID and the presence of symptoms detected. In the second case study, a proof of principle of the fault diagnosis part of the 4S3F method was successfully performed on the same HVAC system extracting possible component and control faults from the P&ID. A Bayesian Network diagnostic, which mimics the way of diagnosis by HVAC engineers, was applied to identify the probability of all possible faults by interpreting the symptoms. The diagnostic Bayesian network (DBN) was set up in accordance with the P&ID, i.e., with the same structure. Energy savings from fault corrections were estimated to be up to 25% of the primary energy consumption, while the HVAC system was initially considered to have an excellent performance. In the third case study, a demand-driven ventilation system (DCV) was analysed. The analysis showed that the 4S3F method works also to identify faults on an air ventilation system.