Dienst van SURF
© 2025 SURF
BackgroundPatients undergoing total knee arthroplasty (TKA) often experience strength deficits both pre- and post-operatively. As these deficits may have a direct impact on functional recovery, strength assessment should be performed in this patient population. For these assessments, reliable measurements should be used. This study aimed to determine the inter- and intrarater reliability of hand-held dynamometry (HHD) in measuring isometric knee strength in patients awaiting TKA.MethodsTo determine interrater reliability, 32 patients (81.3% female) were assessed by two examiners. Patients were assessed consecutively by both examiners on the same individual test dates. To determine intrarater reliability, a subgroup (n = 13) was again assessed by the examiners within four weeks of the initial testing procedure. Maximal isometric knee flexor and extensor strength were tested using a modified Citec hand-held dynamometer. Both the affected and unaffected knee were tested. Reliability was assessed using the Intraclass Correlation Coefficient (ICC). In addition, the Standard Error of Measurement (SEM) and the Smallest Detectable Difference (SDD) were used to determine reliability.ResultsIn both the affected and unaffected knee, the inter- and intrarater reliability were good for knee flexors (ICC range 0.76-0.94) and excellent for knee extensors (ICC range 0.92-0.97). However, measurement error was high, displaying SDD ranges between 21.7% and 36.2% for interrater reliability and between 19.0% and 57.5% for intrarater reliability. Overall, measurement error was higher for the knee flexors than for the knee extensors.ConclusionsModified HHD appears to be a reliable strength measure, producing good to excellent ICC values for both inter- and intrarater reliability in a group of TKA patients. High SEM and SDD values, however, indicate high measurement error for individual measures. This study demonstrates that a modified HHD is appropriate to evaluate knee strength changes in TKA patient groups. However, it also demonstrates that modified HHD is not suitable to measure individual strength changes. The use of modified HHD is, therefore, not advised for use in a clinical setting.
MULTIFILE
OBJECTIVE: To investigate the level of agreement of the behavioural mapping method with an accelerometer to measure physical activity of hospitalized patients. DESIGN: A prospective single-centre observational study. SETTING: A university medical centre in the Netherlands. SUBJECTS: Patients admitted to the hospital. MAIN MEASURES: Physical activity of participants was measured for one day from 9 AM to 4 PM with the behavioural mapping method and an accelerometer simultaneously. The level of agreement between the percentages spent lying, sitting and moving from both measures was evaluated using the Bland-Altman method and by calculating Intraclass Correlation Coefficients. RESULTS: In total, 30 patients were included. Mean (±SD) age was 63.0 (16.8) years and the majority of patients were men (n = 18). The mean percentage of time (SD) spent lying was 47.2 (23.3) and 49.7 (29.8); sitting 42.6 (20.5) and 40.0 (26.2); and active 10.2 (6.1) and 10.3 (8.3) according to the accelerometer and observations, respectively. The Intraclass Correlation Coefficient and mean difference (SD) between the two measures were 0.852 and -2.56 (19.33) for lying; 0.836 and 2.60 (17.72) for sitting; and 0.782 and -0.065 (6.23) for moving. The mean difference between the two measures is small (⩽2.6%) for all three physical activity levels. On patient level, the variation between both measures is large with differences above and below the mean of ⩾20% being common. CONCLUSION: The overall level of agreement between the behavioural mapping method and an accelerometer to identify the physical activity levels 'lying', 'sitting' and 'moving' of hospitalized patients is reasonable.
Objectives: To determine the psychometric properties of a questionnaire to assess fear of movement (kinesiophobia): the Tampa Scale for Kinesiophobia (TSK-NL Heart), and to investigate the prevalence of kinesiophobia in patients attending cardiac rehabilitation.Methods: A total of 152 patients were evaluated with the TSK-NL Heart during intake and 7 days later. Internal consistency, test-retest reliability and construct validity were assessed. For construct validity, the Cardiac Anxiety Questionnaire (CAQ) and the Hospital Anxiety and Depression Scale (HADS) were used. The factor structure of the TSK-NL Heart was determined by a principal component analysis (PCA).Results: After removal of 4 items due to low internal consistency, the TSK-NL Heart showed substantial reliability (intraclass correlation coefficient; ICC: 0.80). A strong positive correlation was found between the TSK-NL Heart and the CAQ (rs: 0.61). Strong positive correlations were found between the TSK-NL Heart and de HADS (Anxiety) (rs: 0.60) and between the TSK-NL Heart and the CAQ (rs: 0.61). The PCA revealed a 3-factor structure as most suitable (fear of injury, avoidance of physical activity, perception of risk). High levels of kinesiophobia were found in 45.4% of patients.Conclusion: The 13-item TSK-NL Heart has good psychometric properties, and we recommend using this version to assess kinesiophobia, which is present in a substantial proportion of patients referred for cardiac rehabilitation.Keywords: Tampa Scale for Kinesiophobia; cardiac rehabilitation; exercise; fear of movement; physical activity; cardiovascular disease