Dienst van SURF
© 2025 SURF
Introduction: Peripheral intravenous cannulation is the preferred method to obtain vascular access, but not always successful on the first attempt. Evidence on the impact of the intravenous catheter itself on the success rate is lacking. Faster visualization of blood flashback into the catheter, as a result of a notched needle, is thought to increase first attempt success rate. The current study aimed to assess if inserting a notched peripheral intravenous catheter will increase first attempt cannulation success up to 90%, when compared to inserting a catheter without a notched needle. Design: In this block-randomized trial, adult patients in the intervention group got a notched peripheral intravenous catheter inserted, patients in the control group received a traditional non-notched catheter. The primary objective was the first attempt success rate of peripheral intravenous cannulation. Intravenous cannulation was performed according to practice guidelines and hospital policy. Results: About 328 patients were included in the intervention group and 330 patients in the control group. First attempt success was 85% and 79% for the intervention and control group respectively. First attempt success was remarkably higher in the intervention group regarding patients with a high risk for failed cannulation (29%), when compared to the control group (10%). Conclusion: This study was unable to reach a first attempt success of 90%, although first attempt cannulation success was higher in patients who got a notched needle inserted when compared to those who got a non-notched needle inserted, unless a patients individual risk profile for a difficult intravenous access.
MULTIFILE
Abstract Aims: To lower the threshold for applying ultrasound (US) guidance during peripheral intravenous cannulation, nurses need to be trained and gain experience in using this technique. The primary outcome was to quantify the number of procedures novices require to perform before competency in US-guided peripheral intravenous cannulation was achieved. Materials and methods: A multicenter prospective observational study, divided into two phases after a theoretical training session: a handson training session and a supervised life-case training session. The number of US-guided peripheral intravenous cannulations a participant needed to perform in the life-case setting to become competent was the outcome of interest. Cusum analysis was used to determine the learning curve of each individual participant. Results: Forty-nine practitioners participated and performed 1855 procedures. First attempt cannulation success was 73% during the first procedure, but increased to 98% on the fortieth attempt (p<0.001). The overall first attempt success rate during this study was 93%. The cusum learning curve for each practitioner showed that a mean number of 34 procedures was required to achieve competency. Time needed to perform a procedure successfully decreased when more experience was achieved by the practitioner, from 14±3 minutes on first procedure to 3±1 minutes during the fortieth procedure (p<0.001). Conclusions: Competency in US-guided peripheral intravenous cannulation can be gained after following a fixed educational curriculum, resulting in an increased first attempt cannulation success as the number of performed procedures increased.
MULTIFILE
Objective: This study aims to assess the comparative effectiveness of a conventional splitting needle or a peelable cannula vs. the modified Seldinger technique (MST) by utilizing a dedicated micro-insertion kit across various clinically significant metrics, including insertion success, complications, and catheter-related infections. Methods: We conducted a retrospective observational cohort study using an anonymized data set spanning 3 years (2017-2019) in a large tertiary-level neonatal intensive care unit in Qatar. Results: A total of 1,445 peripherally inserted central catheter (PICC) insertion procedures were included in the analysis, of which 1,285 (89%) were successful. The primary indication for insertion was mainly determined by the planned therapy duration, with the saphenous vein being the most frequently selected blood vessel. The patients exposed to MST were generally younger (7 ± 15 days vs. 11 ± 26 days), but exhibited similar mean weights and gestational ages. Although not statistically significant, the MST demonstrated slightly higher overall and first-attempt insertion success rates compared to conventional methods (91 vs. 88%). However, patients undergoing conventional insertion techniques experienced a greater incidence of catheter-related complications (p < 0.001). There were 39 cases of catheter-related bloodstream infections (CLABSI) in the conventional group (3.45/1,000 catheter days) and eight cases in the MST group (1.06/1,000 catheter days), indicating a statistically significant difference (p < 0.001). Throughout the study period, there was a noticeable shift toward the utilization of the MST kit for PICC insertions. Conclusion: The study underscores the viability of MST facilitated by an all-in-one micro kit for neonatal PICC insertion. Utilized by adept and trained inserters, this approach is associated with improved first-attempt success rates, decreased catheter-related complications, and fewer incidences of CLABSI. However, while these findings are promising, it is imperative to recognize potential confounding factors. Therefore, additional prospective multicenter studies are recommended to substantiate these results and ascertain the comprehensive benefits of employing the all-in-one kit.
LINK